Columbus AGM 304/5 Advanced
The Columbus AGM 304/5 climate controller can be ordered for various application as a OEM product
The Columbus AGM 304/5 function:
-
5 stage controller
-
0 to 110 volt operation
-
2 temperature sensor output
-
1 humidity sensor input
-
temperature reduction curve
-
temperature and humidity graph
-
color touch screen
-
minimum ventilation timer
-
cooling with humidity control
-
Circulation of minimum ventilation fan
The Columbus AGM 304/5 Advance climate controller is an advance easy to use 5 stage controller developed specially for poultry and pig raising.
The AGM 304/5 have a color touch screen for easy operation.
The AGM 304/5 can be ordered in different variation, operate the Heater, Minimum ventilation, Tunnel ventilation and fan stage, Air inlet / Cooling curtain and Cooling
The AGM 304/5 have a automatic temperature reduction curve for automatic calculation of the minimum ventilation. A minimum ventilation timer for the first fan stage and a timer for the
cooling. The cooling will stop if the humidity is high.
The AGM 304/5 will collect information for the last 24 hour and show temperature, humidity , on a graph.
TheAGM 304/5 display can be translated into any languish.
It is possible to set that the minimum fan group will rotate between the 4 fan group so each time another fan group will be the minimum ventilation group to give a even air flow
in the house.
AGM 304/5 standard version
The Columbus AGM 304/5 A function: 4 Fan group, 1 Cooling,
The first group minimum ventilation group include a on/off timer.
The Cooling with a on/off timer, Cooling will stop when humidity is high. Automatic temperature curve will deduct the requested temperature for the whole growing period.
The Columbus AGM 304/5 A function:
4 Fan group, 1 Cooling.
The first group minimum ventilation group include a on/off timer.
The Cooling with a on/off timer, Cooling will stop when humidity is high.
Automatic temperature curve will deduct the requested temperature for the whole growing period.
The Columbus AGM 304/5 B function:
3 Fan group, 1 Cooling, 1 Heat
The first group minimum ventilation group include a on/off timer.
The Cooling with a on/off timer, Cooling will stop when humidity is high.
Automatic temperature curve will deduct the requested temperature for the whole growing period.
The Columbus AGM 304/5 C function:
3 Fan group, 1 Cooling, 1 Heat Minimum ventilation by variable
speed control 0 to 10 volt.
The Cooling with a on/off timer. Cooling will stop when humidity is high.
Automatic temperature curve will deduct the requested temperature for the whole growing period.
The Columbus AGM 304/5 D function:
1 Fan group, 1 Cooling, 1 Heat Minimum ventilation by variable
speed control 0 to 10 volt.
inlet/ curtain control.
The Cooling with a on/off timer, Cooling will stop when humidity is high.
Automatic temperature curve will deduct the requested temperature for the whole growing period.